This paper deals with the problem of estimating the pose of a moving rigid body by measuring the length of six wires attached to it. Since wires can be seen as extensible legs, this problem is equivalent to that of solving the forward kinematics of a six-degree-of-freedom parallel manipulator. Among all possible locations for the attachments on the moving object, the "3-2-1" configuration is shown to exhibit a large number of favorable properties. The performance analysis of this particular configuration is addressed by finding analytic expressions for the estimated pose covariance matrix and the expected value of the pose estimation error, or bias error, which has been omitted in the previous analysis of wire-based tracking devices. This analysis takes advantage of a formulation for trilateration based on Cayley-Menger determinants, which is mathematically more tractable compared to previous ones, because all terms involved are determinants with geometric meaning. This accommodates a more thorough investigation of the properties of the device.

Performance Analysis of a 3-2-1 Pose Estimation Device

OTTAVIANO, Erika;CECCARELLI M.
2005-01-01

Abstract

This paper deals with the problem of estimating the pose of a moving rigid body by measuring the length of six wires attached to it. Since wires can be seen as extensible legs, this problem is equivalent to that of solving the forward kinematics of a six-degree-of-freedom parallel manipulator. Among all possible locations for the attachments on the moving object, the "3-2-1" configuration is shown to exhibit a large number of favorable properties. The performance analysis of this particular configuration is addressed by finding analytic expressions for the estimated pose covariance matrix and the expected value of the pose estimation error, or bias error, which has been omitted in the previous analysis of wire-based tracking devices. This analysis takes advantage of a formulation for trilateration based on Cayley-Menger determinants, which is mathematically more tractable compared to previous ones, because all terms involved are determinants with geometric meaning. This accommodates a more thorough investigation of the properties of the device.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11580/9599
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
social impact