Background: Effective vaccines are now available for SARS-CoV-2 in the 2nd year of the COVID-19 pandemic, but there remains significant uncertainty surrounding the necessary vaccination rate to safely lift occupancy controls in public buildings and return to pre-pandemic norms. The aim of this paper is to estimate setting-specific vaccination thresholds for SARS-CoV-2 to prevent sustained community transmission using classical principles of airborne contagion modeling. We calculated the airborne infection risk in three settings, a classroom, prison cell block, and restaurant, at typical ventilation rates, and then the expected number of infections resulting from this risk at varying percentages of occupant immunity. Results: We estimate the setting-specific immunity threshold for control of wild-type SARS-CoV-2 to range from a low of 40% for a mechanically ventilation classroom to a high of 85% for a naturally ventilated restaurant. Conclusions: If vaccination rates are limited to a theoretical minimum of approximately two-thirds of the population, enhanced ventilation above minimum standards for acceptable air quality is needed to reduce the frequency and severity of SARS-CoV-2 superspreading events in high-risk indoor environments.
The vaccination threshold for SARS-CoV-2 depends on the indoor setting and room ventilation
Stabile L.;Buonanno G.;
2021-01-01
Abstract
Background: Effective vaccines are now available for SARS-CoV-2 in the 2nd year of the COVID-19 pandemic, but there remains significant uncertainty surrounding the necessary vaccination rate to safely lift occupancy controls in public buildings and return to pre-pandemic norms. The aim of this paper is to estimate setting-specific vaccination thresholds for SARS-CoV-2 to prevent sustained community transmission using classical principles of airborne contagion modeling. We calculated the airborne infection risk in three settings, a classroom, prison cell block, and restaurant, at typical ventilation rates, and then the expected number of infections resulting from this risk at varying percentages of occupant immunity. Results: We estimate the setting-specific immunity threshold for control of wild-type SARS-CoV-2 to range from a low of 40% for a mechanically ventilation classroom to a high of 85% for a naturally ventilated restaurant. Conclusions: If vaccination rates are limited to a theoretical minimum of approximately two-thirds of the population, enhanced ventilation above minimum standards for acceptable air quality is needed to reduce the frequency and severity of SARS-CoV-2 superspreading events in high-risk indoor environments.File | Dimensione | Formato | |
---|---|---|---|
Mikszewski, 2021_vaccination_threshold.pdf
solo utenti autorizzati
Tipologia:
Documento in Post-print
Licenza:
DRM non definito
Dimensione
1.35 MB
Formato
Adobe PDF
|
1.35 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.