This paper presents an investigation in terms of degree of unbalance and leakage factor of electrical machines equipped with multiphase windings. The analysis has been carried out through 4800 combinations between slots/poles/phases/layers, analyzing the variability of the leakage factor for each condition and determining the optimal region for its minimization. The obtained results demonstrate that the leakage factor could be considerably reduced with the adoption of slightly asymmetrical windings, which represent a favorable option during the early design stage of electrical machines.

Differential leakage factor in electrical machines equipped with asymmetrical multiphase windings: A general investigation

Marignetti F.;
2019-01-01

Abstract

This paper presents an investigation in terms of degree of unbalance and leakage factor of electrical machines equipped with multiphase windings. The analysis has been carried out through 4800 combinations between slots/poles/phases/layers, analyzing the variability of the leakage factor for each condition and determining the optimal region for its minimization. The obtained results demonstrate that the leakage factor could be considerably reduced with the adoption of slightly asymmetrical windings, which represent a favorable option during the early design stage of electrical machines.
2019
978-1-7281-3703-2
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11580/75633
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
social impact