This paper discusses the influence of thermodynamic correction parameters on measuring the flow rate of natural gas in the reference condition. In particular, the principal aim is to experimentally evaluate the uncertainties of the correction parameters on volumetric flow rate measurement in the reference condition by means of conventional methods. An experimental analysis was carried out on the Italian distribution system which is very interesting from a metrological point of view since there are four different types of natural gas with a pressure and temperature range comprised respectively between 1.1 to 71 bar and 0 to 30°C.
The influence of reference condition correction on natural gas flow measurement
BUONANNO, Giorgio;DELL'ISOLA, Marco
1998-01-01
Abstract
This paper discusses the influence of thermodynamic correction parameters on measuring the flow rate of natural gas in the reference condition. In particular, the principal aim is to experimentally evaluate the uncertainties of the correction parameters on volumetric flow rate measurement in the reference condition by means of conventional methods. An experimental analysis was carried out on the Italian distribution system which is very interesting from a metrological point of view since there are four different types of natural gas with a pressure and temperature range comprised respectively between 1.1 to 71 bar and 0 to 30°C.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.