Electro-Fenton (EF), an advanced oxidation process, can be combined with a biological process for efficient treatment of wastewater containing refractory pollutants such as pharmaceuticals. In this study, a biological process was implemented in a sequencing batch reactor (SBR), which was either preceded or followed by EF treatment. The main goal was to evaluate the potential of two sequences of a combined electrochemical-biological process: EF/SBR and SBR/EF for the treatment of real wastewater spiked with 0.1 mM of caffeine and 5-fluorouracil. The biological removal of COD and pharmaceuticals was improved by extending the acclimation time and increasing concentration of biomass in the SBR. Hardly biodegradable caffeine and COD were completely removed during the EF post-treatment (SBR/EF). During the EF/SBR sequence, complete removal of pharmaceuticals was achieved by EF within 30 min at applied current 800 mA. With a current of 500 and 800 mA, the initially very low BOD5/COD ratio increased up to 0.38 and 0.58, respectively, after 30 min. The efficiency of the biological post-treatment was influenced by the biodegradability enhancement after EF pre-treatment. The choice of an adequate sequence of such a combined process is significantly related to the wastewater characteristics as well as the treatment objectives.

Bioelectro-Fenton: evaluation of a combined biological-advanced oxidation treatment for pharmaceutical wastewater

GANZENKO, Oleksandra;TRELLU, Clement;PAPIRIO, Stefano;ESPOSITO, Giovanni;
2017-01-01

Abstract

Electro-Fenton (EF), an advanced oxidation process, can be combined with a biological process for efficient treatment of wastewater containing refractory pollutants such as pharmaceuticals. In this study, a biological process was implemented in a sequencing batch reactor (SBR), which was either preceded or followed by EF treatment. The main goal was to evaluate the potential of two sequences of a combined electrochemical-biological process: EF/SBR and SBR/EF for the treatment of real wastewater spiked with 0.1 mM of caffeine and 5-fluorouracil. The biological removal of COD and pharmaceuticals was improved by extending the acclimation time and increasing concentration of biomass in the SBR. Hardly biodegradable caffeine and COD were completely removed during the EF post-treatment (SBR/EF). During the EF/SBR sequence, complete removal of pharmaceuticals was achieved by EF within 30 min at applied current 800 mA. With a current of 500 and 800 mA, the initially very low BOD5/COD ratio increased up to 0.38 and 0.58, respectively, after 30 min. The efficiency of the biological post-treatment was influenced by the biodegradability enhancement after EF pre-treatment. The choice of an adequate sequence of such a combined process is significantly related to the wastewater characteristics as well as the treatment objectives.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11580/62832
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 74
social impact