After a survey of the existing Coriolismass flowmeters, all based upon the elastic deformation of the resonant sensor, this paper describes anewtype of Coriolismassflowmeter realised, in a prototypal way, in the DIME laboratories. The flowmeter prototype is composed of two attached elements: a stiff tube and an original system of independent elasticsuspension which lets the whole sensor vibrate. In such a way, the newtype of elasticsuspension permits measurement independent from the elastic properties of the tube, not subject to deformation, realising anewmass flow sensor. The DIME prototype, which is described in the present paper, was studied and realised with the main aim of checking the mechanical behaviour of the newtype of uncoupled elasticsuspension. Being the prototype and not a production-engineered version, for which it is possible to provide the metrological performances, the DIME flowmeter was tested on the DIME calibration facility, and the experimental results, which prove the linear behaviour of the prototype, are reviewed.

A Coriolis mass flowmeter based on a new type of elastic suspension

VIGO, Paolo
1989-01-01

Abstract

After a survey of the existing Coriolismass flowmeters, all based upon the elastic deformation of the resonant sensor, this paper describes anewtype of Coriolismassflowmeter realised, in a prototypal way, in the DIME laboratories. The flowmeter prototype is composed of two attached elements: a stiff tube and an original system of independent elasticsuspension which lets the whole sensor vibrate. In such a way, the newtype of elasticsuspension permits measurement independent from the elastic properties of the tube, not subject to deformation, realising anewmass flow sensor. The DIME prototype, which is described in the present paper, was studied and realised with the main aim of checking the mechanical behaviour of the newtype of uncoupled elasticsuspension. Being the prototype and not a production-engineered version, for which it is possible to provide the metrological performances, the DIME flowmeter was tested on the DIME calibration facility, and the experimental results, which prove the linear behaviour of the prototype, are reviewed.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11580/5843
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni