To promote the diffusion of smart metering, several National Authorities defined strict roll-out procedures of the existing meters with new smart meters. In such scenario, even if new static technologies in gas metering offer very significant potential (such as digital output, absence of moving parts, direct mass measurement), their reliability in some critical conditions typical of natural gas distribution networks (i.e. zero flow, minimum flow-rate, gas quality changes, presence of dust and contaminants, etc.) still has to be demonstrated. A very promising technology for natural gas domestic measurements is represented by thermal mass flow meters, but, unfortunately, gas quality is expected to significantly affect metrological performance of such meters. The authors conducted several metrological tests aimed to verify the sensitivity of such meter with natural gas quality changes. The results of these tests show a not full reliability when CO2 content increases and when gas composition varies

Critical aspects of new domestic static gas meter

CELENZA, Luca;DELL'ISOLA, Marco;FICCO, Giorgio;VIGO, Paolo;
2015-01-01

Abstract

To promote the diffusion of smart metering, several National Authorities defined strict roll-out procedures of the existing meters with new smart meters. In such scenario, even if new static technologies in gas metering offer very significant potential (such as digital output, absence of moving parts, direct mass measurement), their reliability in some critical conditions typical of natural gas distribution networks (i.e. zero flow, minimum flow-rate, gas quality changes, presence of dust and contaminants, etc.) still has to be demonstrated. A very promising technology for natural gas domestic measurements is represented by thermal mass flow meters, but, unfortunately, gas quality is expected to significantly affect metrological performance of such meters. The authors conducted several metrological tests aimed to verify the sensitivity of such meter with natural gas quality changes. The results of these tests show a not full reliability when CO2 content increases and when gas composition varies
2015
978-1-4799-8591-3
978-1-4799-8591-3
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11580/53155
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
social impact