The implementation of an advanced control system for an eleven-level modular converter connected to the power grid via an HVDC transmission line is discussed in this study. The control system's goal is to maintain stable and dependable converter operation under a variety of operating circumstances and grid disruptions. The control system includes a number of control loops, including feedforward compensation loops for voltage, current, and power. In order to share active and reactive power between parallel-connected converters, a droop control approach is also used. Through simulation studies for various scenarios, such as changes in grid voltage and frequency, load variations, and converter faults, the control system is created and validated. The findings show that the suggested control system is capable of effectively controlling the converter's output voltage and power, suppressing harmonic distortion, and ensuring the converter's stable and dependable functioning in the face of grid disruptions. Therefore, the enhanced control method can enhance the HVDC transmission system's performance and dependability, resulting in the creation of a more effective and intelligent power grid. © 2023 IEEE.

Advanced control of eleven level modular converter connected to the power grid via HVDC transmission line

Marignetti, Fabrizio;
2023-01-01

Abstract

The implementation of an advanced control system for an eleven-level modular converter connected to the power grid via an HVDC transmission line is discussed in this study. The control system's goal is to maintain stable and dependable converter operation under a variety of operating circumstances and grid disruptions. The control system includes a number of control loops, including feedforward compensation loops for voltage, current, and power. In order to share active and reactive power between parallel-connected converters, a droop control approach is also used. Through simulation studies for various scenarios, such as changes in grid voltage and frequency, load variations, and converter faults, the control system is created and validated. The findings show that the suggested control system is capable of effectively controlling the converter's output voltage and power, suppressing harmonic distortion, and ensuring the converter's stable and dependable functioning in the face of grid disruptions. Therefore, the enhanced control method can enhance the HVDC transmission system's performance and dependability, resulting in the creation of a more effective and intelligent power grid. © 2023 IEEE.
File in questo prodotto:
File Dimensione Formato  
Advanced_control_of_eleven_level_modular_converter_connected_to_the_power_grid_via_HVDC_transmission_line-1.pdf

solo utenti autorizzati

Tipologia: Documento in Post-print
Licenza: Copyright dell'editore
Dimensione 1.37 MB
Formato Adobe PDF
1.37 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11580/105404
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
social impact